SITE & BUILDING ELECTRICAL · 32+ MEP TOOLS

Construction & Building Electrical Calculators Cable sizing, voltage drop, breakers & motors.

Civil engineers, MEP coordinators, and site electricians get a complete electrical design & verification suite inside the same offline app-covering wiring, protection switchgear, motors, power factor, conduits, and site lighting.

CIRCUITS, CABLES & CONDUITS

Cable sizing, voltage drop & conduit calculators.

Size feeders and sub-circuits accurately for both current-carrying capacity (ampacity) and permissible voltage drop limits.

CBL / 01

Single-Phase & Three-Phase Cable Sizing

Select copper or aluminium conductor cross-section (mm² / AWG) accounting for load kW/kVA/Amps, power factor, ambient temperature, grouping, and installation method.

  • Cu & Al Conductors
  • Derating Factors
  • 1Ø & 3Ø Feeders
VDP / 02

Voltage Drop & Maximum Cable Run Length

Compute exact resistive and reactive (R·cosφ + X·sinφ) voltage drop in Volts and %, and verify compliance against lighting (3%) and power (5%) limits.

  • % Voltage Drop
  • R & X Impedance
  • Max Feeder Length
CND / 03

Conduit Fill, Cable Tray & Trunking Sizing

Calculate total cable outer-diameter area and select PVC/GI conduit or tray dimensions within allowable space-factor fill percentages.

  • Conduit Fill %
  • Cable Tray Width
  • Multi-Cable Runs

PROTECTION, SWITCHGEAR & MOTORS

Breakers, RCDs, fault level, motors & kVAr.

Coordinate protective devices, panel busbars, motor branch circuits, and capacitor banks directly on site.

BRK / 04

MCB, MCCB & ACB Breaker Sizing (Ib ≤ In ≤ Iz)

Match design current, standard breaker trip ratings, B/C/D trip curves, and cable ampacity coordination (`Ib ≤ In ≤ Iz`) for distribution boards and feeders.

  • Ib ≤ In ≤ Iz Check
  • B / C / D Curves
  • MCB · MCCB · ACB
RCD / 05

RCD / RCCB Selection & Discrimination Check

Choose residual current sensitivity (30 mA, 100 mA, 300 mA), AC/A/F/B type, S-type time-delayed upstream selectivity, and upstream-downstream breaker discrimination.

  • 30–300 mA RCCB
  • Type AC / A / F / B
  • Selectivity Check
FLT / 06

Short-Circuit Fault Level (Isc) & Busbar Sizing

Estimate prospective 3-phase and earth-fault kA from transformer kVA/%Z and feeder impedance, and size copper/aluminium panel busbars for continuous & thermal fault ratings.

  • Prospective Isc (kA)
  • Adiabatic k²S²
  • Cu / Al Busbar
MTR / 07

Motor Full-Load Current (FLC), Branch Circuit & Overload

Compute kW/HP motor FLC, DOL vs Star-Delta starter currents, overload relay range, fuse/breaker sizing, and pump/fan shaft & motor power.

  • Motor FLC (kW / HP)
  • Overload & Fuse
  • Pump & Fan Power
PFC / 08

Power Factor Correction (PFC) Capacitor Bank Sizing

Calculate required reactive power (kVAr), capacitor current, detuned reactor options, and kVA demand reduction to lift lagging cosφ to target (e.g. 0.95–0.99).

  • Required kVAr
  • cosφ Improvement
  • kVA Demand Saving
LGT / 09

Indoor Lumen Lighting, Load Schedule & Backup Sizing

Room lux/lumen fixture count, diversity load estimation, kVA-kW-Amps conversions, earthing checks, and inverter/generator backup sizing.

  • Lumen Method Lux
  • kW ↔ kVA ↔ Amps
  • DG & UPS Backup

COMMON QUESTIONS

Field FAQ.

Need support or want to request a calculator? Email support@civilcalcpro.com.

Does CivilCalc Pro check both ampacity and voltage drop when sizing cables?

Yes. Cable sizing tools evaluate derated current-carrying capacity alongside voltage drop limits so long site feeders are not undersized.

Are protection coordination checks like Ib ≤ In ≤ Iz included?

Yes. The Breaker Sizing, RCD/RCCB Selection, Discrimination Check, and Fault Level calculators verify load current, protective device rating, cable thermal withstand, and breaking capacity (Icu/Ics) together.